Specifications

Mode No. Function Data Factory
Setting
Comments
*48: Light Intensity
Adjustment
Adjusts the
exposure lamp
voltage.
100 – 150 100 –150
Default
= 126
The exposure lamp
voltage is adjusted
on the production
line. (The factory
setting is different
for each machine.
When clearing all
memory, the data
of this mode
returns to "126".
49: Fusing
Temperature
Adjustment
Adjusts fusing
temperature.
175 – 190°C 185°C 175 to 190°C in
1°C steps.
If a number over
190 is input, the
CPU sets the
temp. at 190°. If
under 175, 175° is
set.
51: Exposure
Lamp Voltage
Display
Displays the
exposure lamp
voltage with a
reference number.
The exposure
lamp, main motor,
and optics cooling
fans turn on for 10
seconds when the
Enter key is
pressed.
Press the C/S key
to turn this mode
off.
Do not repeat more
than 5 times to
avoid overheating
the optics cavity.
*52: Fusing
Temperature
Display
Displays the fusing
temperature.
54: Vsg
Adjustment
Adjusts Vsg.
Adjust Vsg to 4.0 ±
0.2 using VR102
on the main board.
The main motor
and the ID sensor
LED turn on when
the Enter key is
pressed. The Vsg
voltage is
displayed on the
magnification
indicator.
1 December 1990