Specifications

Mode No. Function Data Factory
Setting
Comments
82: Blue Toner
Density Level
Display
Displays the blue
toner density level
detected by initial
setting (SP #10).
Toner Density Level
= Vsp/Vsg x 100
87: PM Interval
Setting
Sets the interval of
the PM counter.
0: No PM
1: 40K
2: 60K
3: 80K
4: 100K
0
88: PM Counter
Display
The first three
digits are displayed
in the magnification
indicator when the
Enter key is
pressed.
Press the "." key to
display the second
three digits.
Displays contents
of the PM counter.
When the PM
counter is
exceeded, the
Magnification
indicator blinks.
89: PM Counter
Reset
Resets the PM
counter.
1 (NOTE 4) Use this mode
after performing
PM.
93: Maximum
Copy Quantity
Limits the
maximum copy
quantity that can
be entered.
1 – 99 99
98: Clear Counters Clear the following
counters:
Copy Counters
SC Counters
Jam Counters
PM Counter
0: No
1: Yes
DIP switches 101-3
and 4 on the main
board must be on.
99: Clear All
Memory
Clear all counters
and returns all
modes to the
factory setting.
0: No
1: Yes
DIP switches 101-3
and 4 on the main
board must be on.
1 December 1990
4-19