Specifications

2.4 SP-9 ELECTRICAL COMPONENT CHECK
- How to turn electrical components on/off -
1. Enter "9", then press the Enter (#) key while pressing the Point key.
2. Enter the desired output number. (See the following table.)
3. Press the Start key to turn on the electrical component.
4. Press the Clear/Stop key to turn off the electrical component.
CAUTION: To prevent the paper lift gear and sector gear from being dam-
aged, remove the first cassette before turning on the lift clutch so-
lenoid (No. #27).
Output No. Electrical Component
1 Main Motor (PTL and Quenching Lamp)
2 Charge Corona + Standard Grid
(Grid Voltage = –920 volts)
3 Charge Corona + ID Sensor Grid
(Grid Voltage = –660 volts + Vp Correction Factor)
4 Charge Corona + Vrp Grid
(Grid Voltage = –500 volts)
5 Transfer Corona (One sided copy)
6 Transfer Corona (Two sided copy)
8 Separation Corona
9 ID Sensor LED
10 Development Drive Clutch
11 Toner Supply Clutch Solenoid
14 Sorter DC Motor
15 Sorter Wheel Motor (Bin up)
16 Sorter Wheel Motor (Bin down)
17 Registration Clutch
18 1st Paper Feed Clutch Solenoid
19 Relay Roller Clutch Solenoid
23 2nd Paper Feed Clutch Solenoid
24 3rd Paper Feed Clutch Solenoid (used only on the A054 copier)
27 Cassette Lift Clutch Solenoid
28 Duplex Gate Solenoid (Paper tray must be inserted.)
29 Pick-up Roller Release Solenoid
30 Duplex Feed Motor (Stack) (Paper tray must be inserted.)
31 Duplex Feed Motor (Feed) (Paper tray must be inserted.)
32 Duplex Jogger Motor (Home Position) (Paper tray must be inserted.)
33 Duplex Jogger Motor (A4 size) (Paper tray must be inserted.)
34 Duplex Jogger Motor (B5 size) (Paper tray must be inserted.)
35 Duplex Jogger Motor (LT size) (Paper tray must be inserted.)
1 December 1990
4-26