Specifications

2.11 EXPOSURE LAMP POSITION ADJUSTMENT
(HORIZONTAL DIRECTION)
1. Turn off the main switch.
2. Remove the exposure glass. (See Exposure Glass Removal.)
3. Move the first scanner to the cutout.
4. Position a scale [A] next to the sight hole [B] in the reflector cover to form
a right angle for viewing alignment as shown.
5. Look at the lamp filament [C] through the sight hole in parallel with the
scale. The filament should be directly beneath the sight hole.
NOTE: If necessary, use a penlight to illuminate the exposure lamp.
6. Turn screw [D] to adjust the position of the filament.
Counterclockwise: Filament moves to the left (E direction).
Clockwise: Filament moves to the right (F direction).
[A]
[B]
[D]
[C]
[E] [F]
[D]
[B]
1 December 1990
5-25