3.3 INLET SEAL REMOVAL
1. Take out the development unit.
2. Remove the inlet seal plate [A] by working a small blade screwdriver
along the edge of the plate while pressing the stoppers [B] with one finger
as shown.
NOTE: a) Be careful not to damage the stoppers [B] when removing the inlet
seal plate.
b) The inlet seal plate must be replaced (i.e. a new plate must be
installed) when it is removed to adjust the doctor gap or to replace
the development roller.
c) To install a new inlet seal plate, remove the covering from the
2-sided tape [C] and affix the inlet seal [D] to the development unit
lower casing. Tuck both ends of the seal inside the lower casing
as shown.