4. Clean all developer from the development roller [A] with a vacuum
cleaner. Turn the roller to make sure that it is free of developer.
5. Loosen the doctor plate (4 screws).
6. Insert the"GO" gauge [B] in the doctor gap 20mm from the rear side of
the development roller as shown.
7. Press down the doctor plate, and tighten the rear doctor plate screws [C].
8. Repeat the adjustment procedure at the front side of the development
roller.
9. Check the doctor gap (procedure on next page).
20 mm
20 mm
[C]
[B]