Specifications

- Confirmation Procedure -
1. Carefully follow the procedure given here to correctly measure the doctor
gap.
(1) Insert the gauge [A] into the doctor gap 20mm from the front end of
the development roller.
(2) Check the doctor gap at three other points 20mm from the front end of
the development roller, turning the roller 90
°
each time.
(3) Repeat steps (1), (2), and (3) for the rear side of the development
roller.
2. When the gap is 0.53 - 0.67 mm at three points on each side, the gap
has been adjusted properly.
3. If the gap is out of specification at more than one point on either side, re-
peat the adjustment procedure.
[A]
1 December 1990
5-32