Specifications

4.5 TONER OVERFLOW SENSOR REPLACEMENT
1. Remove the cleaning unit.
2. Lower the transport unit.
3. Remove the toner overflow sensor bracket [A] from the duct bracket
(1 screw).
4. Disconnect the connector [B] and remove the toner overflow sensor [C]
from the bracket (1 screw).
[B]
[C]
[A]
1 December 1990