Specifications

9.12 ERASE MARGIN ADJUSTMENT
When: The leading edge erase margin is not within the
adjustment standard.
Purpose: To maintain the correct leading erase margin
Adjustment
Standard:
2.5 ± 1.5 mm (0.1 ± 0.06")
Measure: SP Mode #41 (0.5mm/step, 16 steps)
How: Changes the erase lamp on period.
1. Place a 150 mm scale perpendicular to the left scale on the exposure
glass.
2. Adjust the leading edge erase margin using SP mode #41. Make three
copies and check the erase margin.
9.13 REGISTRATION ADJUSTMENT
When: Registration is not within the adjustment standard.
Purpose: To maintain proper registration
Adjustment
Standard:
0 ± 2 mm (0 ± 0.08")
Measure: SP Mode #42 (0.5mm/step, 16 steps)
How: Changes the registration roller start timing.
1. Place a 150 mm scale perpendicular to the left scale on the exposure
glass.
2. Adjust the registration using SP mode #42. Make three copies and check
the registration.
1 December 1990