13.1.5 Pick-up Solenoid Adjustment
1. Turn off the main switch.
2. Place several sheets of paper [A] over the exposure glass area.
3. Lower the feed-in unit (See Feed-in Unit Removal) without disconnecting
the eight connectors.
4. Turn on the main switch.
NOTE: When the main switch is turned on, the DPS101 setting on the DF
main PCB must be as follows:
1 = ON 3 = OFF
2 = ON 4 = OFF
This is so that the initial check sequence can take place.
[B]
[F] [E]
[C]
[D]
[A]
1 December 1990
8-37