5. Turn off DPS101-1 and 2, then turn on DPS101-3 and 4 [B].
6. Loosen the screw fixing the pick-up solenoid [C].
7. Place the 0.15 mm thickness gauge [D] between the plunger and the sole-
noid.
8 While holding the solenoid, press SW101 [E] on the DF main PCB to en-
gage all DF solenoids.
9. Holding the solenoid securely, move it slowly towards the left, until the
plunger is attracted to the solenoid. Just at this point, tighten the screw.
NOTE: Make sure the pick-up lever is touching the pick-up roller during this
adjustment.
10. Press SW 102 [F] to turn off the solenoids.
11. Turn off DPS101-3 and 4, then turn on DPS101-1 and 2.
12. Turn off the main switch and reassemble the DF.
13. Check the original feed-in operation.
1 December 1990