Specifications

12. REPLACEMENT AND ADJUSTMENT
12.1 DUPLEX TRAY REMOVAL
1. Pull the duplex tray [A] out from the copier.
2. Remove the side inner cover [B] (3 screws).
3. Remove the front inner cover [C] (2 screws).
4. Unhook the pressure spring [D] from the paper lift arm [E] and the eccen-
tric cam.
5. Remove the clamps [F] with a pair of plyers.
6. Disconnect CN702, CN704, and CN706 [G] from the main board.
7. Disconnect the sensor connector [H] from the jogger h. p. sensor.
8. Remove the duplex unit [I] (4 screws and grounding wire) from the tray.
NOTE: Hold both sides of the duplex unit frame when lifting the duplex unit
out of the tray.
[B]
[C]
[A]
[D]
[I]
[E]
[F]
[G]
[H]
[F]
1 December 1990
10-19