12.6 ENTRANCE SENSOR REPLACEMENT
1. Remove the duplex unit from the tray. (See Duplex Unit Removal.)
2. Turn over the duplex unit as shown.
3. Remove the entrance sensor bracket [A] (1 screw).
4. Disconnect the sensor connector [B].
5. Replace the sensor [C].
[C]
[[A]
[B]
1 December 1990