12.7 GATE SOLENOID REPLACEMENT
1.Remove the duplex unit from the tray. (See Duplex Unit Removal.)
2. Replace the gate solenoid [A] (1 screw).
NOTE: When installing a new solenoid, make sure of the following:
a) Positioning pin [B] fits into the hole [C] on the gate solenoid
actuator.
b) Spring [D] is hooked to bracket [E].
[E]
[B]
[A]
[C]
[D]