Specifications

POINTS OF MODEL E TYPE 1 SERVICEABILITY
1. Access to service program mode operation
There are two ways to access an SP mode.
(1) By key operation
(2) By turning on DIP SW101-4 on the main board
All the SP modes except for the following SP modes can be accessed
simply by key operation.
a. SP #27 A3 (DLT) Double Count
b. SP #98 Clear Counters
c. SP #99 Clear All Memory
2. Electrical adjustment and electrical component failure check
All adjustment, sensor/switch check, and electrical component check
except for the following adjustments can be performed by SP mode
(key operation).
a. ADS voltage (Variable resistor on the main board)
b. ID sensor voltage (Variable resistor on the main board)
c. Corona currents (Variable resistor on the power pack)
d. Grid voltage (Variable resistor on the power pack)
3. Less mechanical adjustments
There are only fem mechanical adjustments.
a. Doctor gap adjustment
b. Scanner home position adjustment
c. 4th/5th mirror home position adjustment
d. Scanner drive pulley clearance adjustment
e. Exposure lamp position adjustment
f. Entrance guide plate height adjustment
g. Side-to-side registration adjustment
4. Less PM parts (consumable parts) in the fusing section
The cleaning pad, oil supply pad and oil blade for the oil supply
system are not necessary.
5. Replacement of feed rollers
The replacement procedure for 1st feed rollers will be improved from
production units. (See attached copy.)
6. Replacement of ozone filter
The ozone filter can be replaced very easily. (See attached copy.)
7. Replacement of parts on the duplex unit
The duplex unit can be removed from the copier as a module.
Therefore, access to the parts are easier.