Specifications

3.7 EXPOSURE LAMP VOLTAGE CONTROL
The main board controls the exposure lamp voltage through the ac drive
board. The exposure lamp voltage is based on the base lamp voltage and
various correction factors. The exposure lamp data setting determines the
base lamp voltage. The following table gives the approximate lamp voltage
for each data setting.
Exposure Lamp Data/Voltage Reference Table
Exposure
Lamp Data
Exposure Lamp Voltage
(Standard)
Exposure
Lamp Data
Exposure Lamp Voltage
(Standard)
115V machine
220/240V
machine
115V machine
220/240V
machine
100 57.1 105.9 126 71.9 133.4
101 57.6 106.9 127 72.5 134.5
102 58.2 108.0 128 73.0 135.5
103 58.8 109.1 129 73.6 136.6
104 59.3 110.1 130 74.2 137.6
105 59.9 111.2 131 74.7 138.7
106 60.5 112.2 132 75.3 139.8
107 61.1 113.3 133 75.9 140.8
108 61.6 114.4 134 76.5 141.9
109 62.2 115.4 135 77.0 142.9
110 62.8 116.5 136 77.6 144.0
111 63.3 117.5 137 78.2 145.1
112 63.9 118.6 138 78.7 146.1
113 64.5 119.6 139 79.3 147.2
114 65.0 120.7 140 79.9 148.2
115 65.6 121.8 141 80.5 149.3
116 66.2 122.8 142 81.0 150.4
117 66.8 123.9 143 81.6 151.4
118 67.3 124.9 144 82.2 152.5
119 67.9 126.0 145 82.7 153.5
120 68.5 127.1 146 83.3 154.6
121 69.0 128.1 147 83.9 155.6
122 69.6 129.2 148 84.4 156.7
123 70.2 130.2 149 85.0 157.8
124 70.8 131.3 150 85.6 158.8
125 71.3 132.4
NOTE: Exposure lamp rating: 100V machine: 85V/300W
115V machine: 97V/300W
220/240V machine: 180V/330W
1 December 1990