5. Do steps 4 to 10 of the installation procedure for the A048 copier (page
8-26 to 27).
6. Install the DF position sensor actuator [A] (1 screw).
7. Do steps 11 and 12 of the installation procedure for the A048 copier
(page 8-27).
8. Connect the optics cable connector (2P/Black) [B] to CN206 on the
interface board.
9. Connect the DC harness (4P/White) [C] to the harness connector [D].
10. Disconnect the platen cover position sensor connectors [E] [F], then
connect connector [F] to the DF position sensor connector [G].
NOTE: If this procedure is not done, the APS mode will not function in
platen mode.
11. Secure the grounding wire [H] to the right side plate.
12 Do steps 16 to 25 of the installation procedure for the A048 copier (page
8-28 to 30).
[A]
[F] [E]
[G]
[H]
[C]
[B]
[D]