Specifications

SERVICE CALL AND USER CODE TABLE
SERVICE CALL CODE
E-CODE CONTENTS SP Mode No.
(SC Counter)
11 Exposure Lamp Error
The feed back signal beomes higher than 4.2 volts (r.m.s)
for 1.0 second when the exposure lamp is on, or it
becomes higher than 1.0 volt (r.m.s) for 1.0 second when
the exposure lamp is off.
SP Mode #122
(Exposure
Lamp)
12 Exposure Lamp Error
The feed back signal falls below 0.5 volt (r.m.s) for 1.0
second when the exposure lamp is on, or the exposure
lamp stays on for longer than 10 seconds.
13 Zero Cross Signal Error
The CPU does not receive the zero cross signal within
0.56 second.
21 Scanner Home Position Error
The scanner home position sensor remains off (LOW) 8
seconds after the main switch is turned on.
SP Mode #121
(Optics)
22 Scanner Home Position Error
The scanner home position sensor still on (HIGH) 1.0
second after the scanner starts.
28 Lens Home Position Error
The lens home position sensor remains off (LOW) 3.5
seconds after the lens move to the home position.
29 Lens Home Position Error
The lens home position sensor is still on (HIGH) 3.5
seconds after the lens leaves the home position.
2A 4th/5th Mirror Home Position Error
The 4th/5th mirror home position sensor is still on (HIGH)
2.5 seconds after the 4th/5th mirror assembly moves to
the home position.
2B 4th/5th Mirror Home Position Error
The 4th/5th mirror home position sensor is still off (LOW)
2.5 seconds after the 4th/5th mirror assembly leaves the
home position.
52 Fusing Warm-up Error
The temperature detected by the thermistor does not
reach 175
o
C within 100 seconds after the main switch is
turned on.
SP Mode #124
(Fusing
Section)
Refer to
NOTE b)
53 Fusing Overheat
The temperature detected by the thermistor becomes
higher than 240
o
C.
55 Fusing Thermistor Open
The temperature detected by the thermistor does not
reach 2
o
C within 30 seconds after the main switch is
turned on.