Specifications

10.5.2 2nd Feed Station
Four paper size switches (SW4 [A], SW5 [B], SW6 [C], and SW7 [D]) on the
rear frame detect the paper size. The paper size switches are actuated by an
actuator plate [E] on the rear of the paper tray. The paper end guide [F] is
connected to the actuator plate. When the paper end guide is pushed against
the paper stack loaded in the cassette, the actuator plate slides into position
and actuates the appropriate paper size switch.
Paper Size Detection Table (2nd Feed Station)
Paper Size
Switch
Size Indication
4 5 6 7
A3
F (8" x 13")
A4 lengthwise
A4 sideways
B4
0 1 1 1
1 0 1 1
1 0 0 1
1 1 0 1
0 0 1 1
A3
F
A4
A4
B4
11" x 17"
11" x 8 1/2"
8 1/2" x 11"
8 1/2" x 14"
0 1 1 1
1 1 1 0
1 1 0 1
1 0 1 1
0 0 0 0
11" x 17"
8 1/2" x 11"
8 1/2" x 11"
8 1/2" x 14"
Duplex Unit
0: Low (ON)
1: High (OFF)
[F]
[E]
[A]
[B]
[C]
[D]
1 December 1990