15
6. Tightly screw the four cylindrical screws with the hexa-
gon socket (M12), inside the pedestal, from the engine
flange to the spiral casing.
(Only the two screws below are shown in the image)
To fasten the screws, medium-strength screw locking
(Loctite) is to be used. Please refer to Table 6.1.1
Screw Tightening Torque for the correct screw tighten-
ing torque.
Insert the stainless steel cover between the spiral cas-
ing and the engine and tightly screw the four hexago-
nal screws with washers (M5) and the suspension eye-
lets.
7. Place the suction cover onto the pump again
Please refer to Table 6.1.1 Screw Tightening Torque for the
correct screw tightening torque.
6.5 Dismantling the V-ribbed belt
The belt must be changed after 500 hours. In addition, changes can be required due to shifting or tearing on
the belt extreme stress. The V-ribbed belt can be disassembled by means of the following steps:
Caution: Work may only be carried out on it when the pump is shut down and secured against
restarting.
1. First, you need to remove the stainless steel cover and spiral casing. For these points, please refer to
section 6.3 points 1 to 5.
2. Loosen the belt tensioner screw so that you can remove
the whole belt tensioner. Take the spring out of the hold-
er at the belt tensioner and the tensioning screw.
3. Take the V-ribbed belt out of the sprocket of the V-ribbed
disks. To do this, push forward against the direction of
the V-ribbed belt and in the direction of the impeller and
turn the shaft. The V-ribbed belt goes down through the
pressure and repeated rotation.