Operating instructions

Operating manual: Mobile speciality pump Atlantica
SHG SPECHTENHAUSER HOCHWASSER- UND GEWÄSSERSCHUTZ GMBH
Gewerbestraße 3, D-86875 Waal, Germany www.spechtenhauser.de
Tel.: +49 (0)8246.9695-20 shg@spechtenhauser.de
Fax: +49 (0)8246.9695-24 27.02.14 [5]
16
Caution: Danger due to trapping of limbs.
4. Loosen the four cylindrical screws with the hexagon
socket (M8) on the pedestal to the motor flange.
(Only two of the four screws are visible on the image;
the other screws are located opposite)
5. Drive the engine flange out of the pedestal using a
plastic hammer until the entire unit is removed.
6. Remove the V-ribbed belt from the pedestal and replace it. Ensure that the clamping ring is in the rear
pedestal seat. If it has fallen out, put it back in again.
6.6 Mounting the V-ribbed belt
When assembling the impeller, the following steps are to be taken:
Caution: Work may only be carried out on it when the pump is shut down and secured
against restarting.
1. Lay the new V-ribbed belt in the pedestal and ensure
that V-ribbed belt is also threaded when inserting the
unit. Ensure that the clamping ring is in the rear pedestal
seat and properly laid.