Use and Care Manual

OPERATION EB600RT
24 X7505200806
© 11/19 ECHO Incorporated
Starting Warm Engine
The starting procedure is the same
as Cold Start except DO NOT close
the choke.
1. Throttle Lever
Move throttle position lever (A)
to IDLE position.
2. Purge Bulb
Pump purge bulb (C) until fuel is
visible. Pump bulb an additional
4 or 5 times.
3. Recoil Starter
Pull recoil starter handle (D) and
engine should start. Do not use
choke (B)
Note: If engine does not start
after 5 pulls, use cold
start procedures.
Stopping Engine
1. Throttle Lever
Release throttle trigger. Move
Throttle Lever (A) forward to idle
position and allow engine to
return to idle before shutting off
engine.
2. Throttle Lever
Move Throttle Lever (A) all the
way forward to STOP position.
If engine does not stop when stop switch is moved to STOP
position, close choke - COLD START position - to stall engine.
Have your Shindaiwa dealer repair stop switch before using unit
again.
A
B
C
D
A