Owner's Manual

T3000 MAINTENANCE
X7508162400 23
© 07/2016 ECHO Inc.
Note: The battery comes partially charged from the factory and needs to be fully charged before first use.
Note: Charge the battery when it no longer produces sufficient power to operate the trimmer or when battery
lights indicate that the battery is low.
1. Plug charger AC cord into 120V AC outlet..
2. Align ridges on battery with grooves on charger, and slide
battery into charger.
3. During normal charging, the charger LED (B) will blink
continuously GREEN.
If charger detects a problem, LED blinks RED. Remove battery
from charger, clear obstructions from contacts and reinstall
battery into charger. If battery is outside acceptable temperature
range (0°C to 60°C or 32°F to 140°F) LED remains RED.
4. When charging is complete, LED will remain GREEN.
Note: A fully discharged battery pack will charge in about 72 minutes.
5. Verify battery is fully charged by removing battery from
charger, then pressing battery charge status button (C), and
checking LED display (D).
1 green light indicates that the battery has 0-25% charge.
2 green lights indicate that the battery has 25-50% charge.
3 green lights indicate that the battery has 50-75% charge.
4 green lights indicate that the battery has 75-100% charge.
6. Disconnect battery charger from power supply.
A
B
C
D