MV88plus Video MV88+ Video Kit The ShurePlus MV88 video app user guide. Version: 4.
Shure Incorporated Table of Contents Using the Apple Watch with ShurePlus MOTIV MV88plus Video MV88+ Video Kit 3 General Description 3 Features Connect your Apple Watch to the MOTIV recording app.
Shure Incorporated MV88plus Video MV88+ Video Kit General Description ® The Shure MV88+ Video recording app provides instant video recording with uncompressed audio for your mobile device. Customize the sound with digital signal processing (DSP) preset modes, adjustable gain, and stereo width control. Features • Compatible with iOS, Android, PC and Mac devices. Note: See https://www.shure.com/MOTIVcompatibility for information on recommended Android devices.
Shure Incorporated • Sample rate: 44.1 kHz, 48 kHz • Video resolution: 720p, 1080p, 4K • Frame rate: 24 fps, 30 fps, 60 fps ⑤ Reverse Camera Use the front-facing camera to shoot selfie videos. ⑥ Settings Tap the app settings sprocket to select light or dark theme appearance, to find version information, help materials, and to send feedback. ⑦ Record/Stop Button ⑧ Device Setup Access advanced settings for your audio device. See Device Setup section for more information.
Shure Incorporated ② Connected Device Status/Recording Length/Focus Lock Status will display the model name of the connected MOTIV device. Recording length is displayed in hours, minutes, and seconds. The red dot will flash when video is recording. See the Visual Settings topic for more information on focus and exposure. ③ Zoom Level Pinch the screen to adjust your zoom level for a closer view of your subject. ④ Record/Stop Button Start and stop video recording.
Shure Incorporated Landscape (Horizontal) Video Recording Aim the front of the microphone toward the source. Ensure that the left and right sides of the microphone barrel are facing the appropriate sides. Portrait/Selfie (Vertical) Video Recording Aim the microphone toward yourself and select Left Right Swap.
Shure Incorporated Tip: If you begin shooting in portrait mode, video will remain in portrait mode even if device orientation is turned to landscape. Video Interview • To record audio from on-camera audio only, select the CARDIOID polar pattern and point the microphone toward your subject. • To capture the voices of both the on-camera subject and the off-camera interviewer, select the MONO BIDIRECTIONAL polar pattern in the app. Position the microphone with the left and right sides facing each person.
Shure Incorporated MV88+ Outputs • 3.
Shure Incorporated Device Setup Tap Device on the navigation bar to access microphone settings 9/17
Shure Incorporated ① Notifications The top row displays which device is connected. A red flashing dot next to the name let you know whether recording is active. The charms show which advanced features are on. Tap the headphone icon to access direct monitoring control. Tap the lock to lock or unlock the settings. Note: Lock the settings to prevent accidental changes to settings when handling your device during recording. When mic set tings are Locked, the setting screen is grayed out.
Shure Incorporated Direct Monitoring Blend There are two ways to access the Direct Monitoring slider when you want to adjust your monitor source. Tap the input meter to view the mic gain and monitoring blend sliders. Or you can view the slider by tapping the headphone icon in the device settings tab. Use the direct monitoring slider to determine how much of each input you hear. For best results, start monitoring at the mid point and adjust.
Shure Incorporated 75 Hz Low frequency cutoff Provides a 6 dB-per-octave cutoff at 75 Hz. Helps eliminate floor rumble and low-frequency room noise from heating and air conditioning systems. This setting may also be used to compensate for proximity effect or to reduce low frequencies that make an instrument sound dull or muddy. 150 Hz Low frequency rolloff Provides a 6 dB-per-octave rolloff filter at 150 Hz.
Shure Incorporated 5. Placement of the microphone depends on the size of the room, number of people, and instrument volume. If possible, walk around the room and listen to find where it sounds best. 6. Select the correct preset mode for your recording application. Adjust the microphone level and other settings in the app and place the microphone near your source. Note: Advanced settings should be set up before microphone is in place.
Shure Incorporated Note: If your microphone accidentally becomes disconnected during recording, MOTIV will automatically stop the recording. The save file dialog will appear, prompting you to name and save your audio. Record with Confidence with Automatic Save If your microphone accidentally becomes disconnected during recording, MOTIV will automatically stop the recording. The save file dialog will appear, prompting you to name and save your audio.
Shure Incorporated Issue Solution Connect your mobile device to your computer and use file transfer, like iTunes, to down load the file to your desktop. Split your track in two, export both files and recombine them using audio editing software. General troubleshooting. Ensure that your app is updated to the most current version. Make sure that your phone's operating system is updated to the most current version.
Shure Incorporated Polar Pattern Adjustable Width Stereo/Mono Bidirectional/Mono Cardioid/Mid-Side Stereo Principle Mid-Side Supported Audio Format iOS WAV, AAC (Up to 256 KHz) Supported Audio Format Android AAC (Up to 256 KHz) Frequency Response 20 Hz to 20,000 Hz Adjustable Gain Range 0 to +36 dB Sensitivity 37 dBFS/Pa at 1 kHz [1] [2] Maximum SPL 120 dB SPL [2] Limiter Yes Compressor Yes Equalizer 5-band [1] 1 Pa=94 dB SPL [2]At Minimum Gain, Flat Mode Bit Depth Sampling Rate 24 48 kHz
Shure Incorporated Supported Audio Formats Android PCM/WAV Up to 352 KHz AAC 256, 128, 96 iOS PCM/WAV Up to 352 KHz MP4 Audio Audio file extensions: .mp4, .m4a, .m4p, .m4b AAC 256, 128, 96 Certifications Industry Canada ICES-003 Compliance Label: CAN ICES-3 (B)/NMB-3(B) Note: Testing is based on the use of supplied and recommended cable types. The use of other than shielded (screened) cable types may degrade EMC per formance.