4) The water outlet of the heat pump should connect to the of the
storage tank.
5) Ensure that all the pipes are tightly connected and test for leaks.
6) Apply insulation onto the pipes and plumbing fittings to minimise heat loss.
hot water outlet port
AIR TO WATER HEAT PUMP WATER HEATERAIR TO WATER HEAT PUMP WATER HEATER
Water Circulating Pipe Connection Instructions:
Cold water
Hot water
Cold water
Hot water
Option B: Single set of water inlet/outlet ports
plus ring main return port
Use a Tee Piece and one-way valve on inlet
cold water pipe from the water storage tank to
add the water circulating inlet pipe to the heat
pump with return water flowing back to the middle
ring main port on the water storage tank.
Cold water
Hot water
2.6 Electrical
SIDDONS water heaters are designed for single-phase 220/240V A/C supply only. A certified
electrician must carry out all electrical work in accordance with regulations including AS3000.
A 15-amp circuit breaker should be installed at the power supply for the hot water unit.
A separate circuit breaker is recommended for each unit in the case of multiple installations.
The connection will require an approved, standard 240V 15A On / Off switch or
Junction Box in close proximity to the heater.
Key points:
1) The heat pump should ideally be supplied with a dedicated 240 Volt 15 Amp power supply
2) The heat pump should ideally be connected using a 15 Amp power cable
3) The heat pump power supply circuit must have a grounding wire
4) Power lines and signal lines should be neat and rational, with strong and weak lines
separated so they cannot interfere with each other; leave appropriate distance between
the lines
5) Electrical maintenance must be done by qualified technicians (refer to circuit diagram
below)
6) Unit control panel Code MK4068
7) Fuse specifications: 5A/250V
) The appliance must be installed in accordance with regulations
Connection
isolating
8
8
Option A: Single set of water inlet/outlet ports
Use a Tee Piece and one-way valve on both pipes
to add the water circulating pipe connections
between the heat pump and water storage tank.
Option C: Double set of water inlet/outlet ports
plus ring main return port
Connect the heat pump water circulating inlet
pipe to the spare cold water inlet port on the water
storage tank with return water flowing back to the
middle ring main port.