Data Sheet
Mechanical installation condition for sensor flush installation possible
Operating voltage rated value 24V
Operating current rated value 600mA
Design of the interface for safety-related
communication
connector M12
Transmission frequency Rated value 125kHz
Enclosure
Material of the enclosure plastic
Material of cable sheath PVC
Actuator
Design of the operating mechanism RFID
Contact
Switching frequency 1Hz
Operating distance 12mm
Safe operating distance OFF 16mm
Safe operating distance ON 10mm
Design of the switching function positive switching
Number of switching contacts for signaling function
● safety-related
1
Connections/ Terminals
Type of electrical connection M12 plug, 8-pole
Wire length maximum 30m
Safety related data
Safety Integrity Level (SIL) acc. to IEC 61508 3
Category acc. to EN 954-1 4
Supply voltage
Supply voltage 26.4...20.4V
Inputs/ Outputs
Output current 0.5A
Output current at safety-related output maximum 0.25A
Display
Evaluation version required yes
Installation/ mounting/ dimensions
Mounting type screw fixing
Certificates/ approvals
3SE6315-1BB03 Subject to change without notice
Page 2/
5
09/13/2019 © Copyright Siemens