Data Sheet

China RoHS compliance Yes
Reference designation according to DIN EN 81346-2 K
Ambient conditions
Ambient temperature during operation
● min.
0°C
● max.
55°C
Ambient temperature during storage/transportation
● Storage, min.
-25°C
● Storage, max.
70°C
● Transportation, min.
-25°C
● Transportation, max.
70°C
Air pressure acc. to IEC 60068-2-13
● Operation, min.
860hPa
● Operation, max.
1080hPa
● Storage, min.
660hPa
● Storage, max.
1080hPa
Altitude during operation relating to sea level
● Installation altitude above sea level, max.
2000m
Relative humidity
● Operation at 25 ℃, max.
95%
● Operation at 50 ℃, max.
50%; 95 % at 25 °C, decreasing linearly to 50 % at 50 °C
Vibrations
● Vibration resistance during operation acc. to
IEC 60068-2-6
10 ... 58 Hz / 0.075 mm, 58 ... 150 Hz / 1 g
● Vibration resistance during storage acc. to IEC
60068-2-6
5 ... 8.5 Hz / 3.5 mm, 8.5 ... 500 Hz / 1 g
Shock testing
● Shock resistance during operation acc. to IEC
60068-2-27
15 g / 11 ms / 3 shocks/axis
● Shock resistance during storage acc. to IEC
60068-2-29
25 g / 6 ms / 1 000 shocks/axis
Dimensions
Width 56mm
Height 285mm
Depth 122mm
last modified:
09/12/2019
6BK1943-1AA50-0AA0 Subject to change without notice
Page 3/
3
09/14/2019 © Copyright Siemens