User Manual

II
Fire & Security Products
Siemens Building Technologies Group
07.2001
5.8.5 Structure 1562 (attr = RTFIRE): ALARM remote transmission channel
element.....................................................................................................53
5.8.6 Structure 1562 (attr = RTFAULT): FAULT remote transmission channel
element.....................................................................................................54
5.8.7 Structure 1562 (attr = RTOTHER): OTHER remote transmission channel
element.....................................................................................................55
5.8.8 Structure 1563: Remote transmission device element .............................56
5.8.9 Structure 1564: Alarmhorn (under area CAC control) ..............................56
5.8.10 Structure 1565: Alarmhorn .......................................................................56
5.9 Hierarchical level: FUNCTION UNIT ........................................................56
5.9.1 Structure 1301: Function unit DS11-I line.................................................56
5.9.2 Structure 1302: Function unit MS9I Line ..................................................58
5.9.3 Structure 1303: Function unit DS11-A Line ..............................................60
5.9.4 Structure 1310: Function unit DS11-C line ...............................................62
5.9.5 Structure 1320: Function unit Digital I/O interface....................................63
5.9.6 Structure 1340: Function unit Supply monitoring......................................64
5.9.7 Structure 1390: Function unit display panel (CI11 only).........................65
5.9.8 Structure 1391: Function unit FBA panel (CI11 only) .............................66
5.9.9 Structure 1392: CC11 VDS Interface Part 1.............................................67
5.9.10 Structure 1393: CC11 VDS Interface Part 2.............................................69
5.9.11 Structure 1395: Function unit EXTINGUISHING control module ............71
5.9.12 Structure 1396: Function unit LON interface part 1 ..................................72
5.9.13 Structure 1397: Function unit LON interface part 2 ..................................73
5.10 Hierarchical level: STATION.....................................................................74
5.10.1 Structure 1201: CC11 Control unit ...........................................................74
5.10.2 Structure 1202: CT11 Terminal ................................................................77
5.10.3 Structure 1203: CK11 Gateway................................................................78
5.10.4 Structure 1210: CI11 Compact control unit ..............................................81
5.10.5 Structure 1211: CC11 Control unit (Remote) ...........................................81
5.11 Polling Procedure .....................................................................................82
5.11.1 Telegram repertoire ..................................................................................82
5.11.2 Example: Polling a CS11 Systems ...........................................................82
5.12 Time Telegram .........................................................................................83
6 Examples.................................................................................................84
6.1 Alarms ......................................................................................................84
6.1.1 Local alarm in DAY mode.........................................................................84
6.1.2 General alarm in day mode ......................................................................85
6.1.3 General alarm in night mode ....................................................................86
6.1.4 Extinguishing sequence............................................................................87
6.2 Faults........................................................................................................88
6.2.1 Detector fault ............................................................................................88
6.3 Others.......................................................................................................88
6.3.1 Organization changeover .........................................................................88
6.3.2 Switching a detection zone.......................................................................88
6.3.3 Switching a detection zone to TEST.........................................................89
7 Terminology and abbreviations ............................................................90
8 APPENDIX A: Telegram list CS11 V5.1x..............................................90