Tips for Integrating with an OPC client
6
Possible difficulties in integrating an OPC client
76
Building Technologies A6V10062407_a_en
Fire Safety & Security Products 30.06.2013
Selecting the computer DCOM configuration
Note 1: You must be authorized to use dcomcnfg.exe (administrator) – ask your
system administrator to set your DCOM if you are not.
Note 2: Some changes in DCOM settings require rebooting the computer for changes
to take an effect (for example, DCOM enable/disable).
6.4.2.4 General DCOM settings
General tab
This tab only contains an optional Description field, which you can use to store a
comment text.
Options tab
The Options tab contains some general parameters that should be kept in the default
settings unless you have very a specific reason for modifying them. The default values
are:
Transaction timeout (sec) = 60
Application Proxy RSN = < blank >
Check local store … = Enabled