3 Configuration
3.1 Configuration checklist
Verify that you have satisfied the items needed in the first checklist before proceed-
ing to the configuration checklist that follows.
ITEMS NEEDED FOR CONFIGURATION
The intrusion system architecture: number of control units (PC6010) and interfaces
(PC6442)
The encryption key for the communication security (=0 if no encryption is required).
The local address (1 to 32) for each control unit.
Note: the address is automatically assigned by Composer sequentially. Therefore, the
units should be inserted following the address sequence, from 1 to ‘n’.
The metafile(s) generated by the Panel Reader tool (CSV file) OR
the exact informa-
tion on the control units internal configuration.
The exact connection to the NK8000 unit (NK822x).
Plug-ins needed:
Plug-in #354101 (PC6442 interface)
Plug-in #354001 (PC6010 control unit)
These are both installed during the installation procedure.
CONFIGURING A MAXSYS
1. Add the folder(s) required for identifying the location of the MAXSYS in the project
structure tree.
p. 13
2. Add the MAXSYS main node (PC6442 interface) to the new folder
p. 13
3. Set the encryption key, if used
p. 13
4. Add the MAXSYS control unit (Panel Application)
p. 14
5a. Import the metafile
p. 14
-- or --
5b. Configure the objects manually
p. 16
6. Repeat steps 2 to 4 for all the MAXSYS units of the system
7. Link the MAXSYS to the communication network
p. 16
8. Repeat steps above for all the MAXSYS systems in the project
9. Download the configuration
p. 17