Specification

29
Wire Ranges (Line, Load and Neutral)
per NEC requirements
Accessories – 2 and 3 Pole Type "DT" Switches Only
Maximum Horsepower Ratings Fused
1-Phase AC 3-Phase AC
Ampere 250V
Rating 240V 240V 480V 600V DC
30 3 7
1
/2 15 20 5
60 10 15 30 50 10
100 15 30 60 75 20
200 15 60 125 150 40
400 125 125 125 50
600 125 50
Use HS Type hubs for 30-200A switches.
Not for fusible stainless or 400A Type 12 & 4X switches.
Also for fusible stainless & 400A Type 12 & 4X switches.
Double Throw Switches
General Duty, Accessories, Lug Data and Horsepower Ratings
Catalog
Description Number
30A HNC612
Neutral 60 & 100A
HN263
Kits 200A HNC264
400 & 600A HN678
800 & 1200A HND678
Equipment
30-200A (2) #14-4 AWG HG61234
Ground Kit
400& 600A (1) #14-2/0 HG656
400& 600A (8) #6-350 Kcmil HG678
30-200A with (1) NO & (1) NC Contacts HA161234
Auxilary Contacts
30-200A with (2) NO & (2) NC Contacts HA261234
(HD only)
400-1200A with (1) NO & (1) NC Contacts HA165678
(two required per switch)
400-1200A with (2) NO & (2) NC Contacts HA265678
30-, 240V Kit HR21
30-, 600V Kit & 60A, 240V Kit HR612
Class R Fuse Clip Kits
60A-, 600V Kit HR62
(two required per switch)
100A Kit HR63
200A Kit HR64
100A, 240V Kit HT23
Class T Fuse Adapter Kits
100A, 600V Kit HT63
(two required per pole)
200A-, 240V Kit HT24
200A-, 600V Kit HT64
For
3
/4 Conduit HS075
For 1
Conduit HS100
Type 3R Hubs
For 1
1
/4
Conduit HS125
(30-200A)
For 1
1
/2
Conduit HS150
For 2
Conduit HS200
For 2
1
/2
Conduit HS250
Switch Wire Range (Cu/Al)
Ampere New VBII Design
Range Line, Load and Neutral
30 (1) #14-6
60
(1) #14-6
100 (1) #14-1/0 AWG
200 (1) #6-250
Kcmil
Maximum Horsepower Ratings Non-Fused
O
N
O
F
O
N
Number Type 3R – OutdoorLess Neutral Type 3R – OutdoorWith Neutral
System Voltage of Poles Amps Catalog Number Catalog Number
Double Throw Switches
General Duty Non-Fusible
2
100 DTGNF223R DTGNF223NR
240 200 DTGNF224R DTGNF224NR
Volt AC
3
100 DTGNF323R DTGNF323NR
200 DTGNF324R DTGNF324NR
Accessories – 4 Pole and Type "F" and "NF" 3 Pole Switches Only
Catalog
Description Number
Auxiliary Switch
30-800A
(1) NO, (1) NC
DS200EK1
(tw
o required per switch)
(2) NO, (2) NC
DS200EK2
30-60-100A DSG100GK
Ground Lug Kit
200A DSG200GK
400-600-800A DSG468GK
30-60-100A Use Type HR Hubs
Hubs
200-400A Use Type SSH 4, 4X Hubs
600-800A Use Type SSH 4, 4X Hubs
Neutrals
30-60-100A DT100NK
(for fusible stainless and
200A DT200NK
400A Type 12 & 4X only)
400A Fusible DS800NK
30 5 10 20 30 5
60 10 20 50 60 10
100 15 40 75 100 20
200 15 60 125 150 40
400-800 125 250 350 50
Replacement Parts – 2 and 3 Pole Type "DT" Switches Only
Catalog
Description Number
Type 1, 3R & 12 Replacement Handle 30-200A
HHD61234
Type 4X Replacement Handle 30-200A HHD61234S
Type 4X Replacement Handle 400-1200A HHD65678
30-200A – 2, 3 & 4 Pole Switches
Switch Wire Range (Cu/Al)
Ampere New VBII Design
Range Line, Load and Neutral
400
(1) 1/0 AWG - 750 Kcmil or
(2) 1/0 AWG - 250 Kcmil
600 (2) 1/0 AWG - 500 Kcmil
(2) 1/0 AWG - 750 Kcmil or
800
(3) 1/0 AWG - 500 Kcmil
(3) 1/0 AWG - 600 Kcmil or
1200
(4) 1/0 AWG - 500 Kcmil
400-1200A – 2, 3 Pole Switches
Switch Wire Range (Cu/Al)
Ampere Line, Load and Neutral
Range
400
(1) 1/0 AWG - 300 Kcmil or
(2) 1/0 AWG - 750 Kcmil
600 (2) 250- 500 Kcmil
600 (3) 250- 500 Kcmil
400-800A – 4 Pole Switches
The following ground lugs are provided as standard in 200A and
larger switches 200-(1) #14-4 Cu/Al 400-800A-(3) #6-250MCM Cu/Al.
One aux. required for normal and one required for emergency switch
line base.