Installation Guide

Accessories and wire ranges
Accessories – 2 and 3 pole type “DT” switches only
Description
Catalog
number
Neutral kits
30A
60 & 100A
200A
400 & 600A
800 & 1200A
HNC612
HN263
HNC264
HN678
HND678
Equipment ground kits
30-200A
400 & 600A
800-1200A
(2) #14-4 AWG
(4) #14-2/0
(8) #6-350 Kcmil
HG61234
HG656
HG678
Auxiliary contacts (HD only) (two required per switch)
30-200A
30-200A
400-1200A
400-1200A
with (1) NO & (1) NC contact
with (2) NO & (2) NC contacts
with (1) NO & (1) NC contact
with (2) NO & (2) NC contacts
HA161234
HA261234
HA165678
HA265678
Class R fuse clip kits (two required per switch)
30A, 240V kit
30A, 600V kit/60A, 240V kit
60A, 600V kit
100A Kit
200A Kit
HR21
HR612
HR62
HR63
HR64
Class T fuse adapter kits (two required per pole)
100A, 240V Kit
100A, 600V Kit
200A, 240V Kit
200A, 600V Kit
HT23
HT63
HT24
HT64
Type 3R hubs (30-200A)
For ³⁄₄” Conduit
For 1” Conduit
For 1 ¹⁄₄” Conduit
For 1 ¹⁄₂” Conduit
For 2” Conduit
For 2 ¹⁄₂” Conduit
ECHS075
ECHS100
ECHS125
ECHS150
ECHS200
ECHS250
Accessories – 4 pole and type “F” and “NF” 3 pole
switches only
1)
For replacement line bases, load bases, mechanisms and lugs, see page 3-34 of
the SPEEDFAX.
2)
4 pole switches rated 20HP at 600V, 3 phase.
Description Catalog number
Neutral kits (for 3 pole switches only)
100A
200A
400 and 600A fusible
400A 3P non-fusible
DT100NK
DT200NK
DS800NK
DT600NK
Auxiliary switch (two required per switch)
30-800A
DS200EK1 (1) NO, (1) NC
DS200EK2 (2) NO, (2) NC
Ground lug kit
30-60-100A
200A
400-600-800A
DSG100GK
DSG200GK
DSG468GK
Hubs
30-60-100A
400A
Use Type HR hubs (3R)
Use Type SSH 4, 4X hubs
Replacement parts – 2 and 3 pole switches only
1)
Description Catalog number
30-200A
Type 1, 3R & 12 replacement handle
Type 4X replacement handle
HHD61234
HHD61234S
400-1200A
Replacement handle HHD656
Wire ranges (line, load and neutral) per NEC requirements
Switch
ampere rating
Wire range (Cu/Al) new VBII design
Line, load and neutral
30-200A – 2, 3 & 4 pole switches
30
60
100
200
(1) #14-6
(1) #14-2
(1) #14-1/0 AWG
(1) #6-250 Kcmil
400-1200A – 2 & 3 pole switches
400
600
800
1200
(1) 1/0 AWG-750 Kcmil or
(2) 1/0 AWG-250 Kcmil
(2) 1/0 AWG-500 Kcmil
(2) 1/0 AWG-750 Kcmil or
(3) 1/0 AWG-400 Kcmil
(3) 1/0 AWG-600 Kcmil or
(4) 1/0 AWG-500 Kcmil
400-800A – 4 pole switches
400
600
800
(2) 1/0 AWG-300 Kcmil or
(1) 1/0 AWG-750 Kcmil
(2) 250-500 Kcmil
(3) 250-500 Kcmil
Maximum Horsepower Ratings
Ampere
rating
1 Phase AC 3 Phase AC
250
DC240V 240V 480V 600V
Fused
30
60
100
200
400
600
3
10
15
15
7¹⁄₂
15
30
60
125
125
15
30
60
125
125
20
50
75
150
125
5
10
20
40
50
50
Non-fused
30
60
100
200
400-800
5
10
15
15
10
20
40
60
125
20
50
75
125
250
30
2)
60
100
150
350
5
10
20
40
50
DTF362