User manual

AT Command Set
MC35_ATC_01_V05.00 Page 217 of 256 15.07.2002
at^spic
^SPIC: 1
OK
at+cpin=4713
+CME ERROR: incorrect password
at^spic
^SPIC: 63
OK
at+cpin=4714
+CME ERROR: incorrect password
at^spic
^SPIC: 63
8.33 AT^SPLM Read the PLMN list
Test command
AT^SPLM=?
Response
OK
Parameter
See execute command
Execute command
AT^SPLM
Response
TA returns the list of operator names from the ME. Each operator code <nu-
mericn> that has an alphanumeric equivalent <alphan> in the ME memory is re-
turned.
^SPLM: numeric <numeric1>,long alphanumeric <alpha1><CR><LF>
^SPLM:.....OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameter
<numericn> string type; operator in numeric form; GSM location area identifica-
tion number
<alphan> string type; operator in long alphanumeric format; can contain up to
16 characters
Reference
Siemens
Note
See also GSM 07.07: +COPN, +COPS