User manual

AT Command Set
MC35_ATC_01_V05.00 Page 225 of 256 15.07.2002
8.39 AT^SSDA Set Display Availability
Use the AT^SSDA command to specify whether your MC35 product is designed to provide a display.
If there is one available, AT^SSDA enables or disables the mobile station to present incoming
Class 0 short messages directly on the display. The command is not required for other short mes-
sage Classes.
Test command
AT^SSDA =?
Response
^SSDA: (list of supported <da>s)
Parameter
See write command
Read command
AT^ SSDA?
Response
^SSDA: <da> OK
Parameter
See write command
Write command
AT^SSDA=
<da>
Response
OK
Parameter
<da>: display availability
0 the mobile station is not capable of displaying short messages
1 the mobile station is capable of displaying short messages
Please note that the setting is stored volatile, i.e. after restart or reset, the default
value 0 will be restored. Also, there is no way to store AT^SSDA to the user de-
fined profile.
Reference
Siemens
Note
If a mobile station is able to display short messages, class 0 messages can be
displayed immediately. If the mobile station has no display, class 0 messages
shall be treated as though there was no message class.
Refer to GSM 03.38.
The setting of <da> influences the behaviour of the <mt> parameter in the com-
mand AT+CNMI. This is the only effect of this command. If <da>=1 and <mt>=1 or
3, then Class 0 short messages will be treated as if <da>=0 and <mt>=2. For de-
tails on AT+CNMI refer to Chapter 5.10.
Multiplex protocol:
If using <da>=1 and <mt>=1 on one instance, all other instances have to use
<mt>=0.