User's Manual

Table Of Contents
Planning the RF300 system
4.2 Field data for transponders, readers and antennas
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
49
Note
Possible reader-transponder combinations
The tables of the following section show the possible reader
-transponder combinations.
4.2.1
Field data of RF300 transponders
The limit distances (S
g
) and operating distances (S
a
) along with the length of the
transmission window for each reader-transponder combination are listed in the tables below.
In dynamic mode, make sure that rectangular transponders cross the antenna field in the
longitudinal direction.
Table 4- 2 Field data RF310R reader
Length of the transmission
window (L)
Operating distance (S
a
)
Limit distance (S
g
)
RF320T
30
1...23
26
RF330T
30
2...18
21
RF340T
40 2...36 41
RF350T
45
2...47
53
RF360T
45
2...60
68
RF370T
70
2...45
60
All values are in mm
The values relate to the RF310R reader as of version "D".
Table 4- 3 Field data RF340R reader
Length of the transmission
window (L)
Operating distance (S
a
)
Limit distance (S
g
)
RF320T
45
1...20
25
RF330T
40
2...20
24
RF340T
80
2...50
65
RF350T
80
2...60
75
RF360T
90
2...65
85
RF370T
85
5...60
80
RF380T
90
5...80
100
All values are in mm