50 System Manual, 07/2016, C79000-G8976-C345-0x
Table 4- 4 Field data RF350R reader / ANT 1
Length of the transmission
window (L)
Operating distance (S
a
)
Limit distance (S
g
)
RF320T
45
1...30
40
RF330T
40 1...25 30
RF340T
80
2...55
70
RF350T
80
2...65
85
RF360T
90
2...75
100
RF370T
85
5...65
85
RF380T
90
5...90
110
All values are in mm
Table 4- 5 Field data RF350R reader / ANT 3
Length of the transmission
window (L)
Operating distance (S
a
)
Limit distance (S
g
)
RF320T
??
1...16
20
RF330T
??
1...16
20
RF340T
??
2...32
40
RF350T
??
2...35
42
RF360T
??
2...40
50
All values are in mm
Table 4- 6 Field data RF350R reader / ANT 18
Diameter of the transmis-
sion window (L
d
)
Operating distance (S
a
)
Limit distance (S
g
)
RF320T
10
0...10
15
RF330T
10
0...11
13
RF340T
20
0...20
25
All values are in mm
Table 4- 7 Field data RF350R reader / ANT 30
Diameter of the transmis-
sion window (L
d
)
Operating distance (S
a
)
Limit distance (S
g
)
RF320T
15
0...15
20
RF330T
22
0...15
18
RF340T
25 0...30 35