User's Manual

Table Of Contents
Planning the RF300 system
4.2 Field data for transponders, readers and antennas
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
51
Diameter of the transmis-
sion window (L
d
)
Operating distance (S
a
)
Limit distance (S
g
)
RF350T
25
0...35
40
RF360T
?? 2...25 35
All values are in mm
Table 4- 8 Field data RF380R reader
Length of the transmission window
Operating distance
(S
a
)
Limit distance (S
g
)
in the x direction (L
x
)
in the y direction (L
y
)
RF320T
100
40
2...45
60
RF330T
120
30
5...45
52
RF340T
120
50
2...80
105
RF350T
140
60
2...100
125
RF360T
160
70
2...120
150
RF370T
160
65
5...100
135
RF380T
180
75
5...125
160
All values are in mm
The RF380R with MLFB 6GT2801-3AB10 allows the transmission output power to be set
with the aid of the "distance_limiting" input parameter (you will find more detailed information
in "Function manual FB 45
(https://support.industry.siemens.com/cs/ww/en/view/21738808
)"). For this, values from
approx. 0.5 W to approx. 2.0 W can be set in 0.25 W increments. Depending on the setting,
the change to the transmission output power increases the performance in the lower
operating distance (low performance) or in the upper limit distance (high performance).
The "distance_limiting" range of values is from:
02 (= 0.5 W) through
05 (= 1.25 W; default value) to
08 (= 2 W).
Note
A 'distance_
limiting' value setting outside of the range of "02 to 08" leads to the default
setting 5 and does not generate an error message.
You will find more information on this subject in the chapter "
Minimum clearances (Page 59
)"
section "Minimum distance from reader to reader".
You will find precise information about the parameters in "Product Information "FB 45 and
FC 45 input parameters for RF300 and ISO
transponders"
(
https://support.industry.siemens.com/cs/ww/en/view/33315697)".