User's Manual
Table Of Contents
- SIMATIC RF300
- Legal information
- Table of contents
- 1 Introduction
- 2 Safety information
- 3 System overview
- 4 Planning the RF300 system
- 4.1 Fundamentals of application planning
- 4.1.1 Selection criteria for SIMATIC RF300 components
- 4.1.2 Transmission window and read/write distance
- 4.1.3 Width of the transmission window
- 4.1.4 Impact of secondary fields
- 4.1.5 Setup help of the readers of the second generation
- 4.1.6 Permissible directions of motion of the transponder
- 4.1.7 Operation in static and dynamic mode
- 4.1.8 Dwell time of the transponder
- 4.1.9 Communication between communications module, reader and transponder
- 4.2 Field data for transponders, readers and antennas
- 4.3 Installation guidelines
- 4.4 Chemical resistance of the transponders
- 4.5 Guidelines for electromagnetic compatibility (EMC)
- 4.1 Fundamentals of application planning
Planning the RF300 system
4.2 Field data for transponders, readers and antennas
SIMATIC RF300
52 System Manual, 07/2016, C79000-G8976-C345-0x
4.2.2
Field data of ISO transponders (MDS D)
The limit distances (S
g
) and operating distances (S
a
) along with the length of the
transmission window for each reader-transponder combination are listed in the tables below.
Observe the following information for field data of ISO transponders:
● A maximum median deviation of ±2 mm is possible in static mode (without affecting the
field data).
● In dynamic mode, make sure that rectangular transponders cross the antenna field in the
longitudinal direction.
Table 4- 9 Field data RF310R reader
Length of the transmission
window (L)
Operating distance (S
a
)
Limit distance (S
g
)
MDS D100
40
2...93
105
MDS D124
30 2...64 72
MDS D126
90
2...65
73
MDS D139
105 5...96 109
MDS D160
30
2...39
44
MDS D165
130
2...90
102
MDS D200
120
2...84
95
MDS D261
80
2...74
83
MDS D324
30
2...47
63
MDS D339
85
5...74
84
MDS D400
90
2...104
117
MDS D423
55
2...35
45
MDS D424
35
1...70
78
MDS D425
30
1...22
25
MDS D426
90
5...100
113
MDS D428
30
1...43
48
MDS D460
30
1...37
41
MDS D524
35
1...70
78
MDS D525
??
??
??
MDS D526
90
5...100
113
MDS D528
30 1...43 48
All values are in mm
The values relate to the RF310R reader as of version "D".