User's Manual
Table Of Contents
- SIMATIC RF300
- Legal information
- Table of contents
- 1 Introduction
- 2 Safety information
- 3 System overview
- 4 Planning the RF300 system
- 4.1 Fundamentals of application planning
- 4.1.1 Selection criteria for SIMATIC RF300 components
- 4.1.2 Transmission window and read/write distance
- 4.1.3 Width of the transmission window
- 4.1.4 Impact of secondary fields
- 4.1.5 Setup help of the readers of the second generation
- 4.1.6 Permissible directions of motion of the transponder
- 4.1.7 Operation in static and dynamic mode
- 4.1.8 Dwell time of the transponder
- 4.1.9 Communication between communications module, reader and transponder
- 4.2 Field data for transponders, readers and antennas
- 4.3 Installation guidelines
- 4.4 Chemical resistance of the transponders
- 4.5 Guidelines for electromagnetic compatibility (EMC)
- 4.1 Fundamentals of application planning
Planning the RF300 system
4.2 Field data for transponders, readers and antennas
SIMATIC RF300
54 System Manual, 07/2016, C79000-G8976-C345-0x
Length of the transmission
window (L)
Operating distance (S
a
)
Limit distance (S
g
)
MDS D424
50
2...60
80
MDS D425
40 2...25 35
MDS D426
110
0...85
110
MDS D428
40
2...35
50
MDS D460
40
2...35
50
MDS D524
50
2...60
80
MDS D525
??
??
??
MDS D526
110
0...85
110
MDS D528
40
2...35
50
All values are in mm
Table 4- 12 Field data RF350R reader / ANT 3
Diameter of the transmis-
sion window (L
d
)
Operating distance (S
a
)
Limit distance (S
g
)
MDS D124
??
0...35
42
MDS D160
??
1...16
20
MDS D324
??
2...32
40
MDS D422
??
1...12
15
MDS D423
??
0...24
30
MDS D424
??
0...42
48
MDS D425
??
0...16
20
MDS D428
??
0...25
32
MDS D460
??
0...18
25
All values are in mm
Table 4- 13 Field data RF350R reader / ANT 12
Diameter of the transmis-
sion window (L
d
)
Operating distance (S
a
)
Limit distance (S
g
)
MDS D117
2
0...3
4
MDS D127
2
0...3
4
MDS D160
15
0...8
15
MDS D421
6
0...3
5
MDS D428
15
1...10
17
MDS D460
8
1...10
14
MDS D521
6
0...3
5
MDS D528
15
1...10
17
All values are in mm