User's Manual

Table Of Contents
Planning the RF300 system
4.2 Field data for transponders, readers and antennas
SIMATIC RF300
58 System Manual, 07/2016, C79000-G8976-C345-0x
Table 4- 20 Field data RF350R reader / ANT 1
Length of the transmission
window (L)
Operating distance (S
a
)
Limit distance (S
g
)
MDS E600
80
5...110
140
MDS E611
80 5...110 140
MDS E624
55
2...65
85
All values are in mm
Table 4- 21 Field data RF350R reader / ANT 12
Diameter of the transmis-
sion window (L
d
)
Operating distance (S
a
)
Limit distance (S
g
)
MDS E623
6
0...3
5
All values are in mm
Table 4- 22 Field data RF350R reader / ANT 18
Diameter of the transmis-
sion window (L
d
)
Operating distance (S
a
)
Limit distance (S
g
)
MDS E623
10
0...6
8
MDS E624
27
2...24
34
All values are in mm
Table 4- 23 Field data RF350R reader / ANT 30
Diameter of the transmis-
sion window (L
d
)
Operating distance (S
a
)
Limit distance (S
g
)
MDS E624
30
1...35
46
All values are in mm