User's Manual
Table Of Contents
- SIMATIC RF300
- Legal information
- Table of contents
- 1 Introduction
- 2 Safety information
- 3 System overview
- 4 Planning the RF300 system
- 4.1 Fundamentals of application planning
- 4.1.1 Selection criteria for SIMATIC RF300 components
- 4.1.2 Transmission window and read/write distance
- 4.1.3 Width of the transmission window
- 4.1.4 Impact of secondary fields
- 4.1.5 Setup help of the readers of the second generation
- 4.1.6 Permissible directions of motion of the transponder
- 4.1.7 Operation in static and dynamic mode
- 4.1.8 Dwell time of the transponder
- 4.1.9 Communication between communications module, reader and transponder
- 4.2 Field data for transponders, readers and antennas
- 4.3 Installation guidelines
- 4.4 Chemical resistance of the transponders
- 4.5 Guidelines for electromagnetic compatibility (EMC)
- 4.1 Fundamentals of application planning
Planning the RF300 system
4.2 Field data for transponders, readers and antennas
SIMATIC RF300
60 System Manual, 07/2016, C79000-G8976-C345-0x
RF310R
RF340R
RF350R /
ANT 1
RF350R /
ANT 3
RF350R /
ANT 12
RF350R /
ANT 18
RF350R /
ANT 30
RF380R
RF382R
1)
MDS D424
≥ 100 180 ≥ 180 ?? -- ≥ 50 ≥ 80 ≥ 360 ≥ 100,
180
MDS D425
≥ 70
≥ 100
≥ 100
??
--
--
≥ 60
≥ 250
--
MDS D426
≥ 120
≥ 120
≥ 140
--
--
≥ 30
≥ 60
≥ 400
--
MDS D428
≥ 100 ≥ 150 ≥ 150 ?? ≥ 30 ≥ 50 ≥ 60 ≥ 300 --
MDS D460
≥ 100 ≥ 150 ≥ 150 ?? ≥ 30 ≥ 50 ≥ 60 ≥ 300 ≥ 100,
120
MDS D521
--
--
--
--
≥ 15
≥ 15
--
--
--
MDS D522
--
--
--
--
--
≥ 30
≥ 40
--
--
MDS D524
≥ 100 180 ≥ 180 -- -- ≥ 50 ≥ 80 ≥ 360 ≥ 100,
180
MDS D525
≥ 70
≥ 100
≥ 100
??
--
--
≥ 60
≥ 250
--
MDS D526
≥ 120
≥ 120
≥ 140
--
--
≥ 30
≥ 60
≥ 400
--
MDS D528
≥ 100
≥ 150
≥ 150
--
≥ 30
≥ 50
≥ 60
≥ 300
--
MDS E600
2)
≥ 120 ≥ 240 ≥ 240 -- -- -- -- -- --
MDS E611
2)
≥ 120 ≥ 240 ≥ 240 -- -- -- -- -- --
MDS E623
2)
-- -- -- -- ≥ 15 ≥ 15 -- -- --
MDS E624
2)
≥ 100 180 ≥ 180 ?? -- ≥ 50 ≥ 80 -- --
1)
The first value is the minimum distance of the transponders in the horizontal field, the second value is the minimum
distance of the transponders in the vertical field.
2)
Product to be discontinued; only relevant for migration projects.
All values are in mm, relative to the operating distance (S
a
) between reader and transponder, and between transponder
edge and transponder edge
Minimum distance from reader to reader
Table 4- 26 Minimum distances reader
RF310R to
RF310R
RF340R to
RF340R
RF380R to
RF380R
1)
RF382R to
RF382R
with 2 readers ≥ 150 ≥ 200 ≥ 400 ≥ 200
with several
readers
≥ 200 ≥ 250 ≥ 500 ≥ 200
All values are in mm