User's Manual

Table Of Contents
Planning the RF300 system
4.3 Installation guidelines
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
67
Transponder
RF310R reader
Without metal
On metal
Flush-mounted
in metal
(20 mm all-
round)
MDS D139
1)
Without metal
100
90
80
On metal; distance 30 mm
100
90
80
Flush-mounted in metal;
distance all round 100 mm
100 90 80
MDS D160
1)
Without metal
100
90
80
On metal; distance 10 mm
75
75
75
MDS D165
Without metal
100
90
85
On metal; distance 25 mm
90
80
75
MDS D200
1)
Without metal
100
90
80
On metal; distance 20 mm
80
70
65
Flush-mounted in metal;
distance all round 20 mm
60 60 60
MDS D261
Without metal
100
80
85
On metal; distance 25 mm
90
75
80
MDS D324
1)
Without metal
100
95
75
On metal; distance 15 mm
80
80
75
Flush-mounted in metal;
distance all round 25 mm
80 75 70
MDS D339
without metal
??
??
??
on metal; distance 30 mm
??
??
??
flush-mounted in metal;
distance all round 100 mm
?? ?? ??
MDS D400
1)
Without metal
100
80
75
On metal; distance 20 mm
65
60
55
Flush-mounted in metal;
distance all round 20 mm
55 50 45
MDS D423
Without metal
100
95
90
On metal; distance 0 mm
150
2)
140
2)
140
2)
Flush-mounted in metal;
distance all round 0 mm
70 60 60
MDS D424
1)
Without metal
100
90
80
On metal; distance 15 mm
80
80
70
Flush-mounted in metal;
distance all round 25 mm
60 60 50
MDS D425
Without metal
100
100
95
On metal; distance 0 mm
90
85
80
MDS D426
1)
Without metal
100
90
80
On metal; distance 25 mm
85
80
70
Flush-mounted in metal;
distance all round 50 mm
80 75 65