User's Manual
Table Of Contents
- SIMATIC RF300
- Legal information
- Table of contents
- 1 Introduction
- 2 Safety information
- 3 System overview
- 4 Planning the RF300 system
- 4.1 Fundamentals of application planning
- 4.1.1 Selection criteria for SIMATIC RF300 components
- 4.1.2 Transmission window and read/write distance
- 4.1.3 Width of the transmission window
- 4.1.4 Impact of secondary fields
- 4.1.5 Setup help of the readers of the second generation
- 4.1.6 Permissible directions of motion of the transponder
- 4.1.7 Operation in static and dynamic mode
- 4.1.8 Dwell time of the transponder
- 4.1.9 Communication between communications module, reader and transponder
- 4.2 Field data for transponders, readers and antennas
- 4.3 Installation guidelines
- 4.4 Chemical resistance of the transponders
- 4.5 Guidelines for electromagnetic compatibility (EMC)
- 4.1 Fundamentals of application planning
Planning the RF300 system
4.3 Installation guidelines
SIMATIC RF300
74 System Manual, 07/2016, C79000-G8976-C345-0x
Reader RF350R with ANT 1 and with ISO transponders (MDS D)
Table 4- 39 Reduction of field data due to metal, range as %: Transponder and RF350R with ANT 1
Transponder
ANT 1 without
metal
ANT 1 on metal
ANT 1 mounted
in metal
(40 mm all-
round)
MDS D100
1)
Without metal
100
85
80
On metal; distance 20 mm 70 60 65
Flush-mounted in metal;
distance all round 20 mm
60 45 45
MDS D124
1)
Without metal 100 95 85
On metal; distance 15 mm
85
85
80
Flush-mounted in metal;
distance all round 20 mm
85 80 50
MDS D126
1)
Without metal
100
85
85
On metal; distance 25 mm
85
75
75
Flush-mounted in metal;
distance all round 50 mm
80 70 70
MDS D139
1)
Without metal
100
90
85
On metal; distance 30 mm
95
85
85
Flush-mounted in metal;
distance all round 100 mm
95 85 85
MDS D160
1)
Without metal
100
95
90
On metal; distance 10 mm
85
85
80
MDS D165
Without metal
100
85
85
On metal; distance 25 mm
90
80
75
MDS D200
1)
Without metal
100
85
80
On metal; distance 20 mm
85
75
75
Flush-mounted in metal;
distance all round 20 mm
75 65 65
MDS D261
Without metal
100
90
85
On metal; distance 25 mm
85
80
80
MDS D324
1)
Without metal
100
85
85
On metal; distance 15 mm 90 80 80
Flush-mounted in metal;
distance all round 25 mm
80 75 65
MDS D339
1)
Without metal
100
90
85
On metal; distance 30 mm
95
85
85
Flush-mounted in metal;
distance all round 100 mm
95 85 85
MDS D400
1)
Without metal
100
90
85
On metal; distance 20 mm
80
70
65
Flush-mounted in metal;
distance all round 20 mm
65 60 60