User's Manual
Table Of Contents
- SIMATIC RF300
- Legal information
- Table of contents
- 1 Introduction
- 2 Safety information
- 3 System overview
- 4 Planning the RF300 system
- 4.1 Fundamentals of application planning
- 4.1.1 Selection criteria for SIMATIC RF300 components
- 4.1.2 Transmission window and read/write distance
- 4.1.3 Width of the transmission window
- 4.1.4 Impact of secondary fields
- 4.1.5 Setup help of the readers of the second generation
- 4.1.6 Permissible directions of motion of the transponder
- 4.1.7 Operation in static and dynamic mode
- 4.1.8 Dwell time of the transponder
- 4.1.9 Communication between communications module, reader and transponder
- 4.2 Field data for transponders, readers and antennas
- 4.3 Installation guidelines
- 4.4 Chemical resistance of the transponders
- 4.5 Guidelines for electromagnetic compatibility (EMC)
- 4.1 Fundamentals of application planning
Planning the RF300 system
4.3 Installation guidelines
SIMATIC RF300
84 System Manual, 07/2016, C79000-G8976-C345-0x
Transponder
ANT 30 without metal
ANT 30 mounted in met-
al
(20 mm all-round)
MDS D126
1)
Without metal
100
85
On metal; distance 25 mm 90 75
Flush-mounted in metal;
distance all round 50 mm
85 70
MDS D160
1)
Without metal 100 80
On metal, distance 10 mm
85
75
MDS D324
1)
Without metal
100
80
On metal; distance 15 mm
90
70
Flush-mounted in metal;
distance all round 25 mm
80 65
MDS D422
Without metal
100
85
On metal, distance 0 mm
95
85
Flush-mounted in metal;
distance all round 0 mm
90 80
MDS D423
Without metal
100
80
On metal, distance 0 mm
125
2)
115
2)
Flush-mounted in metal;
distance all round 0 mm
80 70
MDS D424
1)
Without metal
100
85
On metal 15 mm
95
85
Flush-mounted in metal;
distance all round 25 mm
85 75
MDS D425
Without metal
100
80
On metal, distance 0 mm
95
80
MDS D426
1)
Without metal
100
85
On metal; distance 25 mm
90
75
Flush-mounted in metal;
distance all round 50 mm
80 70
MDS D428
Without metal
100
90
On metal, distance 0 mm
95
90
MDS D460
1)
Without metal
100
90
On metal, distance 10 mm
95
85
MDS D522
without metal
??
??
on metal, distance 0 mm
??
??
flush-mounted in metal;
distance all round 0 mm
?? ??
MDS D524
1)
without metal
??
??
on metal 15 mm
??
??
flush-mounted in metal;
distance all round 25 mm
?? ??
MDS D525
without metal
??
??
on metal, distance 0 mm ?? ??