User's Manual

Table Of Contents
Planning the RF300 system
4.3 Installation guidelines
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
87
Transponder
Reader RF380R (ISO mode)
Without metal
On metal
Flush-mounted
in metal
(20 mm all-
round)
MDS D124
1)
Without metal
100
95
90
On metal; distance 15 mm
95
90
85
Flush-mounted in metal;
distance all round 20 mm
70 65 50
MDS D126
1)
Without metal
100
90
80
On metal; distance 25 mm
80
75
70
Flush-mounted in metal;
distance all round 50 mm
75 65 65
MDS D139
1)
Without metal
100
90
75
On metal; distance 30 mm
95
85
70
Flush-mounted in metal;
distance all round 100 mm
90 80 70
MDS D160
1)
Without metal
100
95
90
On metal; distance 10 mm
85
85
80
MDS D165
Without metal
100
90
80
On metal; distance 25 mm
80
75
70
MDS D200
1)
Without metal
100
90
80
On metal; distance 20 mm
80
75
70
Flush-mounted in metal;
distance all round 20 mm
65 60 55
MDS D261
Without metal
100
95
85
On metal; distance 25 mm
85
80
75
MDS D324
1)
Without metal
100
95
85
On metal; distance 15 mm
85
85
80
Flush-mounted in metal;
distance all round 25 mm
70 65 60
MDS D339
1)
Without metal
100
90
80
On metal; distance 30 mm
85
80
75
Flush-mounted in metal;
distance all round 100 mm
80 75 70
MDS D400
1)
Without metal
100
90
80
On metal; distance 20 mm
75
70
60
Flush-mounted in metal;
distance all round 20 mm
60 60 55
MDS D423
Without metal
100
95
85
On metal; distance 0 mm
100
100
90
flush-mounted in metal;
distance all round 10 mm
75 65 60