Planning the RF300 system
4.4 Chemical resistance of the transponders
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
93
Substance
Test conditions
Rating
Concentration [%]
Temperature [°C]
Detergent
high
60 ℃
○○○○
Plasticizer
60 ℃
○○○○
Explanation of the rating
○○○○
Resistant
○○○
Practically resistant
○○
Conditionally resistant
Less resistant
- Not resistant
w.
Water solution
c. s.
Cold saturated
4.4.3
Polyphenylene sulfide (PPS)
The data memory has special chemical resistance to solutions up to a temperature of 200
°C. A reduction in the mechanical properties has been observed in aqueous solutions of
hydrochloric acid (HCl) and nitric acid (HNO3) at 80 °C. The plastic housings are resistant to
all types of fuel including methanol.
Table 4- 57 Chemical resistance - polyphenylene sulfide (PPS)
Substance
Test conditions
Rating
Concentration [%]
Temperature [°C]
Acetone
55 ℃
○○○○
n-Butanol (butyl alcohol)
80 ℃
○○○○
Butanone-2 (methyl ethyl ketone)
60 ℃
○○○○
n-Butyl acetate
80 ℃
○○○○
Brake fluid
80 ℃
○○○○
Calcium chloride (saturated)
80 ℃
○○○○
Diesel fuel
80 ℃
○○○○
Diethyl ether
23 ℃
○○○○
Frigen 113
23 ℃
○○○○
Anti-freeze
120 ℃
○○○○
Kerosene
60 ℃
○○○○
Methanol 60 ℃ ○○○○
Engine oil
80 ℃
○○○○
Sodium chloride (saturated)
80 ℃
○○○○
Sodium hydroxide
30%
80 ℃
○○○○
Sodium hypochlorite
(30 or 180 days)
5%
80 ℃
○○
5% 80 ℃ -