User's Manual
Table Of Contents
- SIMATIC RF300
- Legal information
- Table of contents
- 1 Introduction
- 2 Safety information
- 3 System overview
- 4 Planning the RF300 system
- 4.1 Fundamentals of application planning
- 4.1.1 Selection criteria for SIMATIC RF300 components
- 4.1.2 Transmission window and read/write distance
- 4.1.3 Width of the transmission window
- 4.1.4 Impact of secondary fields
- 4.1.5 Setup help of the readers of the second generation
- 4.1.6 Permissible directions of motion of the transponder
- 4.1.7 Operation in static and dynamic mode
- 4.1.8 Dwell time of the transponder
- 4.1.9 Communication between communications module, reader and transponder
- 4.2 Field data for transponders, readers and antennas
- 4.3 Installation guidelines
- 4.4 Chemical resistance of the transponders
- 4.5 Guidelines for electromagnetic compatibility (EMC)
- 4.1 Fundamentals of application planning
Planning the RF300 system
4.4 Chemical resistance of the transponders
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
95
Substance
Test conditions
Rating
Concentration [%]
Temperature [°C]
Perchloroethylene
-
Acetone
-
Alcohols ○○
Hot water (hydrolysis resistance)
-
Explanation of the rating
○○○○
Resistant
○○○
Practically resistant
○○ Conditionally resistant
○
Less resistant
-
Not resistant
4.4.5
Polyvinyl chloride (PVC)
Table 4- 59 Chemical resistance - polyvinyl chloride (PVC)
Substance
Test conditions
Rating
Concentration [%]
Temperature [°C]
Salt water
5%
○○○○
Sugared water
10%
○○○○
Acetic acid, w.
5%
○○○○
Sodium carbonate, w.
5%
○○○○
Ethyl alcohol, w.
60%
○○○○
Ethylene glycol
50%
○○○○
Fuel B
(acc. to ISO 1817)
○○○○
Human sweat
○○○○
Explanation of the rating
○○○○
Resistant
○○○
Practically resistant
○○
Conditionally resistant
○ Less resistant
-
Not resistant