User's Manual

Table Of Contents
ISO transponder
8.12 MDS D324
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
299
8.12
MDS D324
8.12.1
Characteristics
MDS D324
Characteristics
Area of application Production and distribution logistics
and product identification
Can also be used in harsh environ-
ments under extreme environmental
conditions (e.g. with hig
her temperature
load).
Memory size
992 bytes of EEPROM user memory
Write/read range See section "Field data of ISO tran-
sponders (MDS D) (Page 52)."
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP67; IPx9K
8.12.2
Ordering data
Table 8- 28 Ordering data MDS D324
Article number
MDS D324
6GT2600-3AC00
Table 8- 29 Ordering data MDS D324 accessories
Article number
Spacer
6GT2690-0AK00