Note
Going below the distances
If the distances (a and h) are not observed, a reduction of the field data results. It
is possible
to mount the MDS with metal screws (M3 countersunk head screws). This has no tangible
impact on the range.
8.12.4
Technical specifications
Table 8- 30 Technical specifications of MDS D324
6GT2600-3AC00
Product type designation
SIMATIC MDS D324
Memory
Memory configuration
• UID • 8 bytes
• User memory • 992 bytes EEPROM
• OPT memory • 16 bytes (EEPROM)
Read cycles (at < 40 ℃)
> 10
14
Write cycles (at < 40 ℃)
> 10
6
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data of ISO transponders (MDS D) (Page 52)"
MTBF (Mean Time Between Failures)
228 years
Mechanical specifications
Housing
• Material • Epoxy resin
• Color • Black
Recommended distance to metal
≥ 15 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
• During operation • -25 to +125 ℃
• During transportation and storage • -40 to +140 ℃