User's Manual

Table Of Contents
RF300 transponder
7.3 SIMATIC RF330T
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
217
Figure 7-7 Mounting of the RF330T in metal without clearance
Note
Reduction of the write/read range
Note that when the device is flush
-mounted in metal without a surrounding clearance ≥ 10
mm, the write/read range is significantly reduced.
7.3.4
Technical specifications
Table 7- 7 RF330T technical specifications
6GT2800-5BA00
Product type designation
SIMATIC RF330T
Memory
Memory organization in bytes
Memory configuration
UID 4 bytes EEPROM
User memory 8 KB FRAM
OPT memory 20 bytes EEPROM
Read cycles (at < 40 ℃)
> 10
14
Write cycles (at < 40 ℃) > 10
14
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data of RF300 transponders (Page 49)"
MTBF (Mean Time Between Failures)
1200 years